Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Crossroller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also D4SL-N2NFG-D4 PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material
D4SL-N2NFG-D4
Cable lengths of 3 and 5 m available on standard models D4SL-N2NFG-D4 PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking D4SL-N2NFG-D4 PDF.
(Applicable only to standard models.)Ratings: 1 A at 30 VDC.
LED indicator: With indicator.
Actuator: Sealed pin plunger.
Many Models Including Roller Lever.
Switches are Only 16-mm Thick with Connector.
New center rollerr lever models that enable ganged mounting OMRON INSTRUCTION sheet D4SL-N2NFG-D4 Manual.
of up to 6 Switches.
Cable connectors for easy Switch replacement.
Triple-seal construction to provide IEC IP67 degree of protection.
Operation indicators available for easy monitoring,
(standard indicator is lit when Switch is not operating).
Approved by UL and CSA.
(Ask your OMRON representative for Information on approved models OMRON INSTRUCTION sheet. ) Type of drive rod: adjustable resin ball type.
Small limit switch for Chinese market.
Small longitudinal Asian standard size.
Miniaturization design of the 1/3 of the OMRON longitudinal type limit switch.
Terminal fully open structure, easy wiring OMRON INSTRUCTION sheet.
RoHS correspondence.
Protection structure IP65. Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Flexible rod, Coil spring.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13).
Wide standard operating temperature range:
-40°C to +100°C (standard type) D4SL-N2NFG-D4 INSTRUCTION sheet.
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models aavailable for complex operations D4SL-N2NFG-D4 Manual.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model.)