Compact Vertical Models Sized for Asian.
Standards.
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring D4SL-N3FFA-DN PDF.
RoHS complaint.
Degree of protection: IP65. Actuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO(Snap-action)
D4SL-N3FFA-DN
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available D4SL-N3FFA-DN PDF. )
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N3FFA-DN PDF.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Hinge lever.
Economical, High Utility Enclosed Switch.
Enclosed Switches with Built-in Basic Switches for High,
Repeatability and Durability of 10 Million Operations Minimum.
Panel mount versions have the same operating position as,
Z Basic Switch OMRON INSTRUCTION sheet.
SSuitable for applications demanding higher mechanical,
strength, dustproof and drip-proof properties than those,
on basic switches D4SL-N3FFA-DN Manual.
Resin molded terminal versions are available.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models OMRON INSTRUCTION sheet. ). Release Key Type: Standard (metal).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Solenoid lock Mechanical release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ OMRON INSTRUCTION sheet.
Conduit size (See Note.): M20.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertiion point D4SL-N3FFA-DN INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N3FFA-DN Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.