Direction of Operation Key insertion: Horizontal.
Cable length: 3 m.
2NC (Slow-action).
Slim Safety Door Switches with IP67 Rating.
Slim design with a width of only 17 mm D4SL-N4PDG-DN PDF.
(three-contact models).
Reversible design allowing either front or rear mounting.
Built-in Switches with two- or three-terminal contact.
construction are available.
Operation Key with rubber mounting hole to absorb vibration and shock
D4SL-N4PDG-DN
IP67 degree of protection. Type: M5.
Actuator: Cone-shaped actuator.
Cable length: 1 m.
Detects Objects in Multiple Directions,
with High Sensitivity, Ideal for Robotics,
Slow-action switching mechanism used D4SL-N4PDG-DN PDF.
Gold-plated contact with coil spring capable of switching,
micro current/voltage load while providing high contact reliability.
Inputs directly to microcomputers and programmable controllers.
Three sizes (M10, M8, and M5) and three types of compact actuators.
Easy panel mounting D4SL-N4PDG-DN PDF. Type: Welding / wire type, M3 screw mounting.
Drive rod: rod type Shibai leaf.
Terminal specifications: with wire, under the lead.
Contact specifications: 1b.
The minimum size of the long stroke type can be reliably switch
The body part size is 78% of the previous generation produuct, which is beneficial to the miniaturization of the equipment OMRON INSTRUCTION sheet D4SL-N4PDG-DN Manual.
No swing bars are also used for easy long stroke specifications (OT reference value: 1.4mm).
Without harmful substances to the environment, the lead type has also been lead-free. Release Key Type: Standard (metal) OMRON INSTRUCTION sheet.
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (without indicator).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 4-contact Model,
Insert the built-in switch (A, B, C, D, S, T, U or V) into the blank @ OMRON INSTRUCTION sheet.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertiion point D4SL-N4PDG-DN INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N4PDG-DN Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.