Actuator: Roller lever (metal lever, metal roller).
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches D4SL-N4PFG-D4N PDF.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
D4SL-N4PFG-D4N
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) D4SL-N4PFG-D4N PDF.
Certified standards: UL, EN (TÜV), and CCC. Subminiature Switch with.
Superb Flux Resistance.
One-piece terminal construction to keep out flux.
High operating-position accuracy (±0.25 mm).
enables easy peripheral design and positioning.
Use of pin plunger also allows horizontal operation D4SL-NN4PFG-D4N PDF D4SL-N4PFG-D4N Manual. Head material: Plastic.
Release key position: Bottom.
Release key type: Standard (resin).
Solenoid voltage/indicator: Solenoid: 24 VDC, Orange LED: 10 to 115 VAC/VDC.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch and,
lockmonitor switch contacts)(slow-action) Certified direct,
opening NC contact: 3NC+2NC OMRON INSTRUCTION sheet.
Conduit opening: G1/2.
Best-selling Guard Lock Safety-door.
Switch Available in Several.
Compact, Multi-contact Models.
Selectable Operation Key insertion direction and,
adjustable mounting ensure installation flexibility OMRON INSTRUCTION sheet.
Built-in switches with multiple-contact construction are available.
Key holding force of 1,300 N minimum.
Can be used for either standard loads or microloads.
Lineup includes models with a conduit size of M20.
IP67 degree of protection OMRON INSTRUCTION sheet.
Variety of Metallic Heads Available. Type of drive rod: one-way action roller type (vertical motion).
Conduit size: single catheter type, M20.
Built in switch structure: slow mottion (1NC) D4SL-N4PFG-D4N INSTRUCTION sheet.
Safety limit switch in accordance with global standard EN 50047.
The contact constitutes a complete variety, there is a single point of specification (1NC) and double contact specifications (1NC/1NO, 2NC).
Forcedd open action structure D4SL-N4PFG-D4N Manual.
The slow moving contact structure is adopted to ensure that the contact distance is 4mm.