LK166
Home >> Download >> OMRON >> Manual Download >> OMRON DRT2-HD16C-1 INSTRUCTION Manual PDF

OMRON DRT2-HD16C-1 INSTRUCTION Manual PDF

Brand: OMRON
Product model: DRT2-HD16C-1
Name: remote i/o terminal
Sort: INSTRUCTION Manual
File language: English
File size: 0.36MB
Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also DRT2-HD16C-1 PDF.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection DRT2-HD16C-1
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models DRT2-HD16C-1 PDF.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking DRT2-HD16C-1 PDF.
(Appllicable only to standard models DRT2-HD16C-1 Manual. )Five Types of Sensor for Use in a Wide.
Range of Environments.
D5SN-S01/-S04/-S04-L Sensors have a compact and light,
weight design with an ultra-small diameter of 6 mm.
The D5SN-S01 offers a high resolution of 0 OMRON INSTRUCTION Manual. 1 µm.
D5SN-M05/-M10 Sensors have a robust construction and can,
withstand a horizontal load of 5 N.
D5SN-S01/-S04/-M05/-M10 Sensors ensure IP67 degree of,
protection.
All Sensors have an insulated design. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Crossroller plunger OMRON INSTRUCTION Manual.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON INSTRUCTION Manual.
Cablee lengths of 3 and 5 m available on standard models DRT2-HD16C-1 INSTRUCTION Manual.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation DRT2-HD16C-1 Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products