Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 1 m.
Operation mode: Dark-ON.
Model: PNP output.
Makes Mounting and Installation Simpler and Smoother E2E-C04N03-MC-B1 PDF.
Suitable for Applications in the Rechargeable Battery Industry. Sensing/Setting range: 50 to 500 mm, 5 to 500 mm.
Simply Set the Distance to Reliably.
Detect Workpieces of Various Colors
E2E-C04N03-MC-B1
Reliable detection regardless of color or material.
Black/white error of only 2% max. (E3S-CL1).
Long sensing distance of 500 mm (E3S-CL2).
Eliminates background influence.
(Differential travel of only 2% max. with E3S-CL1 E2E-C04N03-MC-B1 PDF. ).
Metal body with IP67 protection.
Oil resistance (E3S-CL2). Element type: J (IC).
Terminal type: Exposed-terminal Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 35 cm.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2E-C04N03-MC-B1 PDF.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperrature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON INSTRUCTION sheet E2E-C04N03-MC-B1 Manual. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2 OMRON INSTRUCTION sheet.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy OMRON INSTRUCTION sheet.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temmperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2E-C04N03-MC-B1 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2E-C04N03-MC-B1 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.