Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 1 ms.
Sensing distance: 125 to 40 mm (Min. distance set),
25 to 300 mm (Max E2E-C04S12-WC-C2 PDF. distance set) .
Model: PNP output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color
E2E-C04S12-WC-C2
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class.
Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general) E2E-C04S12-WC-C2 PDF.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: -.
Event input: 6 points E2E-C04S12-WC-C2 PDF.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm OMRON INSTRUCTION sheet.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period OMRON INSTRUCTION sheet.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
Thee main body is short, the thickness is only 60mm E2E-C04S12-WC-C2 Manual.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC) OMRON INSTRUCTION sheet.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuaal, RUN/STOP, alarm), interactive display PV/SV E2E-C04S12-WC-C2 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2E-C04S12-WC-C2 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.