Brand: OMRON
Product model: E2E-C06N04-CJ-C2
Name: proximity sensor
Sort: INSTRUCTION sheet
File language: English
File size: 3.91MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black E2E-C06N04-CJ-C2 PDF.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E2E-C06N04-CJ-C2
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E2E-C06N04-CJ-C2 PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E2E-C06N04-CJ-C2 PDF.
Increased the 3 segment display, which can display the current value / target / operation E2E-C06N04-CJ-C2 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Case color: Black OMRON INSTRUCTION sheet.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, -- OMRON INSTRUCTION sheet.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 OMRON INSTRUCTION sheet. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temmperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2E-C06N04-CJ-C2 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2E-C06N04-CJ-C2 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Small-diameter Proximity Sensor
E2E-C06N04-WC-C1 2M
OMRON Small-diameter Proximity Sensor E2E-C06N04-WC-C1 2M
Appearance: 6.5 dia. Sensing distance: 4 m
OMRON
Small-diameter Proximity Sensor
E2E-C06N04-WC-B2 2M
OMRON Small-diameter Proximity Sensor E2E-C06N04-WC-B2 2M
Appearance: 6.5 dia. Sensing distance: 4 m
OMRON
Small-diameter Proximity Sensor
E2E-C06N04-MC-C1
OMRON Small-diameter Proximity Sensor E2E-C06N04-MC-C1
Appearance: 6.5 dia. Sensing distance: 4 m
OMRON
Small-diameter Proximity Sensor
E2E-C06N04-CJ-C2 0.3M
OMRON Small-diameter Proximity Sensor E2E-C06N04-CJ-C2 0.3M
Appearance: 6.5 dia. Sensing distance: 4 m