Classification: General purpose Models.
Description: Sheathed platinum resistance thermometer.
Temperature range (See note 3.): -200°C to 450°C.
Element type: Pt100 E2EC-C3D1 PDF.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: ASTM316L.
Terminal type: Enclosed terminals.
Page: 6.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E2EC-C3D1
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2EC-C3D1 PDF. Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: Pre-wired.
Body material: Stainless steel.
Thread length (overall length): 49 (62).
Output configuration: NPN E2EC-C3D1 PDF.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
FFull range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels) OMRON INSTRUCTION sheet E2EC-C3D1 Manual.
Modular construction simplifies customization. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2 OMRON INSTRUCTION sheet.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function OMRON INSTRUCTION sheet.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2EC-C3D1 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2EC-C3D1 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.