Screw pitch: M6 (P=1.0).
Lead wire length: 4 m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2EQ-X10D1G-M1GJ-T PDF.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal
E2EQ-X10D1G-M1GJ-T Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1 E2EQ-X10D1G-M1GJ-T PDF.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E2EQ-X10D1G-M1GJ-T PDF. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0 OMRON INSTRUCTION sheet. 5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the statuus of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2EQ-X10D1G-M1GJ-T Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON INSTRUCTION sheet.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Size: 1/8DIN 48 × 96 × 78 (W × H × D) OMRON INSTRUCTION sheet.
Power supply voltage: 100 to 240 VAC.
Input type: Temperature Input Type.
Control method: Valve Control.
Number of alarms: 2.
Communica- tions function: RS-485.
Event input: None.
A position proportional control model for the E5EZ-PRR series.
Depth of only 78 mm.
Various temperature inputs (thermocouple, platinum resistance thermometer,
infrared temperature sensor, voltage inputs) and analog inputs (current, voltage),
Makes use of high-visibility LCD, with three lines of 4-digit display,
for simplicity.
and clarity.
3 lines of display to observe PV/ SV/ MV (valve open percentage),
clearly displaying the state of control (operatiions) E2EQ-X10D1G-M1GJ-T INSTRUCTION sheet.
Event input enables multi-SP selection and run/ stop function.
Alarm delay function.
Communications function.
Able to choose closed/floating control. In floating control,
position proportional control can be perrformed without a potentiometer,
Equipped with a manual output function (equipped with an automatic/manual key),
CE marking and UL/CSA certification E2EQ-X10D1G-M1GJ-T Manual.