LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E2FM-QX10D1 INSTRUCTION sheet PDF

OMRON E2FM-QX10D1 INSTRUCTION sheet PDF

Brand: OMRON
Product model: E2FM-QX10D1
Name: proximity switch
Sort: INSTRUCTION sheet
File language: English
File size: 1.28MB
Sensor type: Diffuse-reflective.
Sensing distance: 100 mm.
Connection method: M12 connector.
Model: NPN output.
A new generation in sensing performance E2FM-QX10D1 PDF.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability E2FM-QX10D1
High EMC protection.
High light immunity.
Robust and waterproof housing. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver) E2FM-QX10D1 PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adoopted in the 256 paragraph,
Visual angle, contrast can be improved E2FM-QX10D1 PDF E2FM-QX10D1 Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors OMRON INSTRUCTION sheet.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay) OMRON INSTRUCTION sheet.
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 4 OMRON INSTRUCTION sheet. 8 dia.
Protective tubing length L: 50 cm.
Lead wire type: Heat resistive.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperatture Sensors E2FM-QX10D1 INSTRUCTION sheet.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2FM-QX10D1 Manual.
Related products
OMRON
Standard Proximity Sensor
E2E-X10D1-M1J-T-Z 0.3M
OMRON Standard Proximity Sensor E2E-X10D1-M1J-T-Z 0.3M
Appearance: M30. Sensing distance: 10 mm. C
OMRON
Proximity Sensor with All-stainless Housing
E2FM-X10C1-M1
OMRON Proximity Sensor with All-stainless Housing E2FM-X10C1-M1
Size: Shielded, M30. Sensing distance: 10 mm
OMRON
Proximity Sensor with All-stainless Housing
E2FM-X10B1 2M
OMRON Proximity Sensor with All-stainless Housing E2FM-X10B1 2M
Size: Shielded, M30. Sensing distance: 10 mm
OMRON
Long-barrel Inductive Proximity Sensor
E2E2-X10D1
OMRON Long-barrel Inductive Proximity Sensor E2E2-X10D1
Appearance: Shielded, M30. Sensing distance: