Large display + status indicator.
Add action mode indicator (ON/D L ON) and teaching status indicator light,
Status at a glance.
Connection type: connector E2FM-X2B1 PDF.
Output mode: PNP output. Small amplifier built-in type photoelectric switch
The body is thin and long, saving space, the volume is only 50 * 50 * 17.4mm
M.S.R function can detect smooth, shiny objects
New photoelectric -IC, enhance anti interference
Power reverse connect, output short circuit and output reverse protection (AC model no)Terminal type: Exposed-lead Models
E2FM-X2B1
Protective tubing diameter D(mm): 3.2 dia.
Protective tubing length L: 35 cm E2FM-X2B1 PDF.
Lead wire type: Heat resistive.
Lead wire length M: 1m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers E2FM-X2B1 PDF.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Free change detection direction.
Detection direction can be according to the front, side (up and down, around 90 units) change OMRON INSTRUCTION sheet.
Can be similar to the feeling of a limit switch installation E2FM-X2B1 Manual.
Type: DC type.
Shape: shield.
Detection distance: 20mm.
Output form: NO NPN + NC (dual output). Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling OMRON INSTRUCTION sheet.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, E5GN-Q03TC-FLK;
Resistance thermometer input, E5GN-Q03P-FLK.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON INSTRUCTION sheet. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E2FM-X2B1 INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E2FM-X2B1 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.