Sensor type: Diffuse-reflective.
Sensing distance: 300 mm.
Connection method: M12 connector.
Model: NPN output.
A new generation in sensing performance E2K-X15MY1 PDF.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability
E2K-X15MY1
High EMC protection.
High light immunity.
Robust and waterproof housing. Sensing method: Distance-settable(BGS Models).
Connection method: Connector(M8, 4 pins).
Response time: 0.5 ms.
Sensing distance: 125 to 40 mm (Min E2K-X15MY1 PDF. distance set),
25 to 300 mm (Max. distance set) .
Model: NPN output .
Compact and Reliable,
Laser Photoelectric Sensor.
Safety and reliability with laser class 1 (JIS and IEC).
Product lineup includes models with distance setting without,
influence of color.
Maximum ambient operating temperature of 55°C and water,
proof construction in E3Z class E2K--X15MY1 PDF E2K-X15MY1 Manual.
Size: M12 (Brass); Single; Shielded.
Sensing distance: 5 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications OMRON INSTRUCTION sheet. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON INSTRUCTION sheet.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON INSTRUCTION sheet.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic // manual, RUN/STOP, alarm), interactive display PV/SV E2K-X15MY1 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2K-X15MY1 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.