Detects Intrusions into Hazardous.
Areas with a Single Beam and.
Complies with International Safety.
Standards. Protective tubing length: 200mm.
Lead wire length: 2m E2KQ-X10ME2 PDF.
Element type: K (CA).
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers
E2KQ-X10ME2
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2KQ-X10ME2 PDF. Size: M8(Stainless steel)(See note 2.); Double; Shielded.
Sensing distance: 2 mm.
Connecting method (See note 1.): Pre-wired.
Body length: Long.
Output configuration: NPN.
Operation mode NC.
A new generation in global applications. Classification: Exclusive Models.
Description: Crimping terminals E2KQ-X10ME2 PDF.
Temperature range (See note 3.): 0°C to 300°C.
Element type: K (CA) J (IC) E2KQ-X10ME2 Manual.
Conductor type: Grounded type.
Class: 2 (0.75).
Protective tubing material: --.
Terminal type: Exposed lead wires.
Page: 21.
A Wide Variety of High-precision.
Temperature Sensors OMRON INSTRUCTION sheet.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON INSTRUCTION sheet. To improve the production capacity and to design the stability of the sensor for detecting the narrow bottle.
In order to stabilize the detection of polyethylene bottles as well as a variety of transparent bottles and greatly increased the S/N ratio OMRON INSTRUCTION sheet. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3.2 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 1m.
A Wide Variety of High-precision.
Temperatture Sensors E2KQ-X10ME2 INSTRUCTION sheet.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2KQ-X10ME2 Manual.