Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling E3S-R2E43 PDF.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -
E3S-R2E43
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance E3S-R2E43 PDF.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat E3S-R2E43 PDF.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the ccontrol output ON/OFF number counting function, can predict the temperature controller internal relay faultFitting materials: Stainless steel (SUS304) OMRON INSTRUCTION sheet E3S-R2E43 Manual.
Count: 1.
Accessories: Description, Slotted/Phillips screws M3,
(with spring and plain washers);
Material, Stainless steel (SUS304); Count, 2 .
Applicable sensor (mounting pitch on sensor side): E3Z pre-wired model OMRON INSTRUCTION sheet.
Page: Dimensions, 7.
Visible light rays.
Visually identify the location of the detection point.
Set up and maintenance is very convenientSize: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1 OMRON INSTRUCTION sheet.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous modelss: ±0 E3S-R2E43 INSTRUCTION sheet. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E3S-R2E43 Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.