Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent:
Detection for single-phase heaters E3S-R81 PDF.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --
E3S-R81
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0 E3S-R81 PDF. 3% of PV (previous models:: ±0 E3S-R81 Manual. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3S-R81 PDF.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4 OMRON INSTRUCTION sheet. 2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, Holder/bracket, Shaft (brace),
Bolt with hexagonal hole, Nut, Phillips screw, Slotted/Phillips screws;
Material, PBT (polybutylene tereph thalate), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304),
Stainless steel (SUSXM7), Stainless steel (SUS304);
Count, 1, 1, 1, 1, 1, 2 OMROON INSTRUCTION sheet E3S-R81 INSTRUCTION sheet.
Applicable sensor (mounting pitch on sensor side): E3Z (25.4),
E3S-R6@/R8@ (20) , E39-R3 OMRON INSTRUCTION sheet.
Page: Dimensions, 14. Size: M12 (Brass); Single; Shielded.
Sensing distance: 2 mm.
Connectting method (See note 1 E3S-R81 Manual. ): M12 Connector.
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications.