High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type E3T-SR32R PDF.
Polarity: none.
Shape: non shield, M30.
Detection distance: 20mm.
Action mode: NC. Appearance: Close-mounting.
Sensing method: Through beam type (with slot).
Connecting method: Connector model (4 poles).
Sensing distance: 5 mm (slot width)
E3T-SR32R
Operating mode: Dark-ON/Light-ON (2 outputs).
Indicator mode: Incident light.
Model: PNP output.
Built-in connector enables,
downsizing and easier connection.
Protective circuit for safe operation E3T-SR32R PDF.
A built-in connector minimizes the shape and dimensional,
requirements.
Two outputs: light-ON and dark-ON.
Complete lineup including seven different shapes.
Safer operation with built-in power supply reverse polarity,
protection.
Output overcurrent protection with a thermal shutdown,
circuit (patent pending) E3T-SR32R PDF.
The indicator can be seen from many directions to enable,
installationn in more locations E3T-SR32R Manual.
Connector with lock that mates with commercially available,
connectors. Sensing method: Retro reflective wit MSR functio.
Connection method: Pre-wired (2 m) OMRON INSTRUCTION sheet.
Sensing distance: 4 m (100 mm )(Using E39-R1S).
Model: PNP output .
Stainless Steel Housing Ideal for Food Industry PAT Pending.
Strong resistance against detergents, disinfectants, and jet liquid flow.
Product lineup includes BGS Reflective Models and Through-beam,
Models with built-in slits OMRON INSTRUCTION sheet.
Certified by Ecolab Europe. Size: 1/16 DIN.
Case color: Black.
Power supply voltage: 100 to 240 VAC.
Input type: Thermocouple or Resistance thermometer.
Auxiliary outputs: 1.
Control output 1: Voltage output (for driving SSR).
New 48 x 48-mm Basic Temperature.
Controller with Enhanced Functions and,
Performance OMRON INSTRUCTION sheet. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous modelss: ±0 E3T-SR32R INSTRUCTION sheet. 5%),
New E5CN-U Models (Plug-in Models) with analog inputs and,
current outputs.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
mannual, RUN/STOP, and alarms) and the PV or SV E3T-SR32R Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.