Detection methods: the firing pattern.
Detection range: 100mm.
Purpose: side type,
Small thin space probe;
Interference prevention function with close installationPhotomicrosensor with light,
modulation for reduced external,
light interference and a,
connector for easy maintenance E3T-ST14R PDF.
Built-in connectors.
Select from four easy-to-use shapes for efficient space,
utilization.
Connectors with locks for safety against vibration
E3T-ST14R
Convenient mounting method using M3 screws.
Wide operating voltage range: 5 to 24 VDC. Appearance: Shielded, 3 dia.
Sensing distance: 0.8 mm.
Model: Operation mode, NO E3T-ST14R PDF.
Subminiature Sensors with.
Long-distance Detection.
Shielded Sensor Heads from 3-mm to M12 diameters that,
can be embedded in metal.
Robotics cables provided as a standard feature (DC 2-Wire Models).
Indicator provided in Amplifier cable for easy confirmation of operation.
Power supply range of 5 to 24 VDC for DC 3-Wire Models E3T-ST14R PDF. High performance price ratio standard type proximity sensor.
Standard cable protector.
The new DC two-wire type.
Non polarr proximity sensor E3T-ST14R Manual.
Type: DC three wire / wire type.
Shape: non shield, M8.
Detection range: 2mm.
Output configuration: NPN.
Action mode: NO OMRON INSTRUCTION sheet. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C OMRON INSTRUCTION sheet.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0 OMRON INSTRUCTION sheet. 5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3T-ST14R INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3T-ST14R Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.