Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E3X-DA11TW PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal)
E3X-DA11TW
Remote SP:4 to 20mA input.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E3X-DA11TW PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP E3X-DA11TW PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/RESET, alarm), interactive display PV/SV E3X-DA11TW Manual.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON INSTRUCTION sheet.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Sensing method: Through-beam OMRON INSTRUCTION sheet.
Connection method: Pre-wired (2 m).
Sensing distance: 25 mm.
No. of opti- cal axes: 1.
Model: PNP output.
Photoelectric Sensor with Grooved.
Design and Easy Settings .
Groove-type Sensor with groove width of 25 mm.
Models are available with one or two light axes.
Models are available with M8 pre-wired connectors OMRON INSTRUCTION sheet. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia.
Protective tubing length L: 50 cm.
Lead wire type: Standard.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperaature Sensors E3X-DA11TW INSTRUCTION sheet.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3X-DA11TW Manual.