Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output E3Z-L61 PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: transfer output (special terminal)
E3Z-L61
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance E3Z-L61 PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E3Z-L61 PDF.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Item: Mark-detecting models(multiple color light sources); Blue LED OMRON INSTRUCTION sheet.
Functions: Timer, Response speed change.
Model: NPN output.
Advanced Fiber Amplifier Units.
Features a Power Tuning function that optimizes light,
reception at the press of a button.
APC circuits to suppress LED aging degradation used with,
4-element LEDs OMRON INSTRUCTION sheet.
2-channell models achieve the thinnest* profile in the industry,
at only 5 mm per channel E3Z-L61 Manual.
2-channel models also offer AND/OR control output.
The E3X-MDA0 with two channels supports an EtherCAT Sensor.
Communications Unit or CompoNet Sensor Communications Unit. Size: 48 x 48mm.
Control output 1: voltage output (SSR driver) OMRON INSTRUCTION sheet.
Control output 2:--.
Auxiliary output: 3 points (common universal).
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type.
Input category: full range multi input.
Heater disconnection, SSR fault detection function: 1 points.
Communication: -.
Event input: 2 points.
Remote SP input: -.
Transfer output: -.
Using large font PV display (white), improve visibility.
Selection, operation and setting.
Functional performance of input and output points.
Support for more extensive range of applications.
Using high PV 15.2mm display (white), improve visibility.
High speed sampling to achieve 50ms.
With auxiliary output (maximum 3 points), event input (maximum 4 points), the transmission output,
Remote SP input function, support for a vaariety of applications E3Z-L61 INSTRUCTION sheet.
E5CC 60mm has a depth of slender body.
The use of communication adapter cable (sold separately) connected with a computer.
After that, no power supply connection can be set.
It can be easily set by CX-Thermmo (sold separately) E3Z-L61 Manual.
Easy to connect with PLC through no program communication.
Combined temperature control device through component communication.