LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E3Z-LL61-M3J INSTRUCTION sheet PDF

OMRON E3Z-LL61-M3J INSTRUCTION sheet PDF

Brand: OMRON
Product model: E3Z-LL61-M3J
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 0.96MB
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling E3Z-LL61-M3J PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Communication: -.
New program type E3Z-LL61-M3J
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 E3Z-LL61-M3J PDF. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E3Z-LL61-M3J PDF.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmeetic functions (AND/OR logic and delay) E3Z-LL61-M3J Manual.
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller OMRON INSTRUCTION sheet. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling OMRON INSTRUCTION sheet.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON INSTRUCTION sheet.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mmanual, RUN/STOP, alarm), interactive display PV/SV E3Z-LL61-M3J INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E3Z-LL61-M3J Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.