LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E3ZM-LS64X INSTRUCTION sheet PDF

OMRON E3ZM-LS64X INSTRUCTION sheet PDF

Brand: OMRON
Product model: E3ZM-LS64X
Name: photoelectric sensors
Sort: INSTRUCTION sheet
File language: English
File size: 22.48MB
Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: relay output.
Auxiliary output: 2 independent points.
Power supply voltage: AC100 ~ 240V E3ZM-LS64X PDF.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 2 point (three phase heater).
Communication: RS-485.
Event input: 2 points E3ZM-LS64X
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications E3ZM-LS64X PDF.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply E3ZM-LS64X PDF.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications.
The main body is short, the thickness is only 60mm OMRON INSTRUCTION sheet.
Easy to use programmable logic controller (PLC) is connected to the programmable loggic controller (PLC) E3ZM-LS64X Manual.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 * 48mm, terminal type OMRON INSTRUCTION sheet.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output) OMRON INSTRUCTION sheet.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state oof the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E3ZM-LS64X INSTRUCTION sheet.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E3ZM-LS64X Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-LS64H
OMRON Compact Photoelectric Sensor  E3ZM-LS64H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-LS86H
OMRON Compact Photoelectric Sensor  E3ZM-LS86H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-T61
OMRON Compact Photoelectric Sensor  E3ZM-T61
Sensing method: Through eam Emitter Recei
OMRON
Compact Photoelectric Sensor
E3ZM-T81
OMRON Compact Photoelectric Sensor  E3ZM-T81
Sensing method: Through eam Emitter Recei