Size: 96 × 96 mm.
Control type: Basic control (1 loop).
Control mode: 1 loop for standard control,
Single-loop heating and cooling control.
Outputs(control/transfer): 2 points: Current and Current E4C-UDA11AN PDF.
Optional functions: Auxiliary outputs (SUB), 4;
Event inputs, 2; Serial communications, Yes.
E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual clarity
E4C-UDA11AN
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight E4C-UDA11AN PDF.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using models with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E4C-UDA11AN PDF. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
root calculation and broken-line approximation).
DeviceNet Communications.
Data setting and monitoring can be performed without special programming. Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 100mm OMRON INSTRUCTION Manual.
Output mode: PNP output. Appearance: Flat,Unshielded.
Sensing distance (variable): 10 mm(4 to 10 mm).
Flat Capacitive Sensor with Separate.
Amplifier.
Ideal for Mounting on Robot Hands.
Flat head is only 5.5-mm thick.
Robotics cable ensures improved flexibility OMRON INSTRUCTION Manual.
Operation indicator on the Sensor.
Easy-to-use connector. High performance price ratio standard type proximmity sensor E4C-UDA11AN Manual.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: none.
Shape: shield, M18.
Detection range: 7mm OMRON INSTRUCTION Manual.
Action mode: NO. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state off the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E4C-UDA11AN INSTRUCTION Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E4C-UDA11AN Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.