Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling E5AC-QQ4ASM-012 PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: transfer output (special terminal)
E5AC-QQ4ASM-012
Remote SP:4 to 20mA input.
Communication: RS-422.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure E5AC-QQ4ASM-012 PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP E5AC-QQ4ASM-012 PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interaactive display PV/SV E5AC-QQ4ASM-012 Manual.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output OMRON INSTRUCTION Manual.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. High performance price ratio standard type proximity sensor OMRON INSTRUCTION Manual.
Standard cable protector.
The new DC two-wire type.
Non polar proximity sensor.
Type: DC two-wire / connector type.
Polarity: none.
Shape: shield, M30.
Detection range: 10mm.
Action mode: NO. Size: M8(Stainless steel)(See note 2.); Single; Shielded OMRON INSTRUCTION Manual.
Sensing distance: 1.5 mm.
Connecting method (See note 1.): M8 Connector (3-pin).
Body length: Long.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Pressure range: 0 to 2.00 kPa.
Digital output: NPN open collector.
Linear output: 4 to 20 mmA E5AC-QQ4ASM-012 INSTRUCTION Manual.
Micropressure Sensor with.
Easy-to-Read Digital Display.
Repeat accuracy of ±1% FS (setting resolution: 0.01 kPa),
high-precision pressure control available.
Compact design (31 × 30 × 30 mm) saves mounting space.
Eassy-to-read red LED indicator E5AC-QQ4ASM-012 Manual.
Analog current output models available (E8Y-A@Y).
Pressure port Rc (PT) 1/8 models available (-R).
EN and UL approved.