LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5AC-QQ4DSM-010 INSTRUCTION Manual PDF

OMRON E5AC-QQ4DSM-010 INSTRUCTION Manual PDF

Brand: OMRON
Product model: E5AC-QQ4DSM-010
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 0.93MB
Size: 48 x 96mm.
Control output 1: voltage output (SSR driver).
Control output 2: relay output.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general) E5AC-QQ4DSM-010 PDF.
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: 1 points.
Communication: RS-485 E5AC-QQ4DSM-010
Event input: 6 points.
Remote SP input: there.
Transfer output: have.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O E5AC-QQ4DSM-010 PDF. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply E5AC-QQ4DSM-010 PDF.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications OMRON INSTRUCTION Manual.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable loogic controller (PLC) E5AC-QQ4DSM-010 Manual.
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve OMRON INSTRUCTION Manual. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-232C OMRON INSTRUCTION Manual.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Teemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AC-QQ4DSM-010 INSTRUCTION Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AC-QQ4DSM-010 Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Digital temperature controller
E5AC-QQ4DSM-000
OMRON Digital temperature controller E5AC-QQ4DSM-000
Size: 96 x 96mm. Control output 1: voltage o
OMRON
Digital temperature controller
E5AC-QQ4ASM-010
OMRON Digital temperature controller E5AC-QQ4ASM-010
Size: 96 x 96mm. Control output 1: voltage o
OMRON
Digital temperature controller
E5EC-RR4DSM-010
OMRON Digital temperature controller E5EC-RR4DSM-010
Size: 48 x 96mm. Control output 1: relay out
OMRON
Digital temperature controller
E5AC-RR4DSM-010
OMRON Digital temperature controller E5AC-RR4DSM-010
Size: 96 x 96mm. Control output 1: relay out