Brand: OMRON
Product model: E5AN-R3H01T-FLK-N
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 1.84MB
Size: 48 x 24mm.
Control output 1: voltage output (SSR driver).
Control output 2:--.
Auxiliary output: 1 points.
Power supply voltage: AC/DC24V.
Terminal type: screw terminal table type (with terminal cover) E5AN-R3H01T-FLK-N PDF.
Input category: full range multi input.
Heater break, SSR fault detection function: -.
Communication: RS-485.
Event input: -.
A small body of 48 * 24mm specifications on the condensation operation, E5_C series of high performance E5AN-R3H01T-FLK-N
Slender body width 48mm * 24mm * 90mm high depth,
The most suitable for small devices / physical and chemical equipment, etc..
Although the small size, but also through the character of the high 10 E5AN-R3H01T-FLK-N PDF. 5mm white PV display to achieve high recognition.
The terminal stage is adopted to disassemble and assemble the structure, which improves the maintenance performance.
The connection method can be selected from a screw terminal and a PUSH-IN fastening terminal E5AN-R3H01T-FLK-N PDF.
High speed sampling of 50ms is realized.
Easy to connect with PLC through no program communication E5AN-R3H01T-FLK-N Manual.
The use of electric communication conversion Village (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CS-Thermo (sold separately) OMRON INSTRUCTION Manual. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: current output.
Control output 2: high life relay output.
Control mode: standard or heating cooling OMRON INSTRUCTION Manual.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON INSTRUCTION Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuall, RUN/STOP, alarm), interactive display PV/SV E5AN-R3H01T-FLK-N INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-R3H01T-FLK-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
Related products
OMRON
Foundation type temperature controller
E5AN-R3HHBT-W-N
OMRON Foundation type temperature controller E5AN-R3HHBT-W-N
Size: 96 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-R3H01T-FLK-N
OMRON Foundation type temperature controller E5EN-R3H01T-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5AN-R3HL-N
OMRON Foundation type temperature controller E5AN-R3HL-N
Size: 96 x 96mm. Ontology: terminal type, ana
OMRON
Foundation type temperature controller
E5EN-Q3H01T-FLK-N
OMRON Foundation type temperature controller E5EN-Q3H01T-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem