Model: Shielded, M8.
Sensing distance: 1.5 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
Proximity Sensor with Resin Case,
with Superb Water Resistance E5AN-RY3BT-N PDF.
IP68 protection.
Mutual interference prevention with models with different,
frequencies is also available. Sensing method: Retro-reflective with MSR function.
Connection method: Pre-wired M8 connector
E5AN-RY3BT-N
Sensing distance: 3 m (150 mm).
Model: NPN output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly.
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models E5AN-RY3BT-N PDF.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment.
High stability with unique algorithm that prevents interference of,
external light. Size: DIN 1/16, 48 X 48 x 60mm.
Power supply voltage: AC100 ~ 240V E5AN-RY3BT-N PDF.
Input type: thermocouple.
Alarm points: -.
Control output: relaay output E5AN-RY3BT-N Manual.
Simple new temperature controller, easy to achieve temperature control.
Good visibility (character height E5CSL:21.7mm, E5CWL:16.2mm (PV), E5EWL:20mm (PV)).
From the front panel depth: 60mm.
Parameter is less, set simple OMRON INSTRUCTION Manual.
Sampling time was reduced to 250ms. Size: 96 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points OMRON INSTRUCTION Manual.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 4.
Transfer output: output (special terminal).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / OMRON INSTRUCTION Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mmanual, RUN/STOP, alarm), interactive display PV/SV E5AN-RY3BT-N INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5AN-RY3BT-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.