Classification: Exclusive Models.
Description: Used for room temperature measurement.
Temperature range (See note 3.): -50°C to 60°C.
Element type: Pt100 E5CC-QQ2DSM-006 PDF.
Conductor type: 3-conductor system.
Class: B.
Protective tubing material: SUS304.
Terminal type: Exposed lead wires.
Page: 22.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work
E5CC-QQ2DSM-006
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5CC-QQ2DSM-006 PDF. Power supply voltage: AC/DC power supply selectable type.
Sensing method: Retro-reflective with MSR function.
Sensing distance: 6 m[100 mm](When using E39-R1), 10 m[100 mm](When using E39-R2) E5CC-QQ2DSM-006 PDF.
Output configu ration: Relay.
Long-distance Photoelectric Sensor.
That Supports AC/DC Power Supplies.
Long sensing distance that is approximately 8,
times that of our conventional model (for the,
Through-beam and Diffuse-reflective models).
(Through-beam: 40 m, Retro-reflective: 7 m, and,
Diffuse-reflective: 2 OMRON INSTRUCTION Manual. 5 m.) .
Improved visibility:
A red LED that makes the spot visible.
Large indicators tthat can be seen even from a,
distance E5CC-QQ2DSM-006 Manual.
Improved operability.
(Enlarged sensitivity adjuster and operation selector)
Freely selectable power supply input (24 to 240 VDC, 24 to 240 VAC) OMRON INSTRUCTION Manual.
(Additional types added to the DC type lineup.)
Models with infrared LEDs are also available. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: current output OMRON INSTRUCTION Manual.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manuual, RUN/STOP, alarm), interactive display PV/SV E5CC-QQ2DSM-006 INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5CC-QQ2DSM-006 Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.