LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CC-RW2DUM-800 INSTRUCTION Manual PDF

OMRON E5CC-RW2DUM-800 INSTRUCTION Manual PDF

Brand: OMRON
Product model: E5CC-RW2DUM-800
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 0.65MB
Detection mode: diffuse reflection type.
Connection mode: lead type (2 m)
Detection distance: infrared 1mmmm.
Output mode: NPN output. Sensing method: Diffuse-reflective Sensors E5CC-RW2DUM-800 PDF.
Appearance: Vertical.
Connection method: Connector (M12).
Sensing distance: 700 mm .
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. The main body: terminal type, temperature input type E5CC-RW2DUM-800
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling E5CC-RW2DUM-800 PDF.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement E5CC-RW2DUM-800 PDF.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive ddisplay PV/SV OMRON INSTRUCTION Manual E5CC-RW2DUM-800 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver OMRON INSTRUCTION Manual.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485 OMRON INSTRUCTION Manual.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensorss E5CC-RW2DUM-800 INSTRUCTION Manual.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to eexecute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault
Related products
OMRON
Digital temperature controller
E5CC-RW1DUM-000
OMRON Digital temperature controller E5CC-RW1DUM-000
Size: 48 x 48mm. Control output: relay outpu
OMRON
Digital temperature controller
E5CC-RW2AUM-000
OMRON Digital temperature controller E5CC-RW2AUM-000
Size: 48 x 48mm. Control output: relay outpu
OMRON
Digital temperature controller
E5CC-RW0DUM-000
OMRON Digital temperature controller E5CC-RW0DUM-000
Size: 48 x 48mm. Control output: relay outpu
OMRON
Digital temperature controller
E5CC-RW1AUM-000
OMRON Digital temperature controller E5CC-RW1AUM-000
Size: 48 x 48mm. Control output: relay outpu