LK166
Home >> Download >> OMRON >> Manual Download >> OMRON E5CC-RX2DSM-001 INSTRUCTION Manual PDF

OMRON E5CC-RX2DSM-001 INSTRUCTION Manual PDF

Brand: OMRON
Product model: E5CC-RX2DSM-001
Name: digital controller
Sort: INSTRUCTION Manual
File language: English
File size: 0.65MB
Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling E5CC-RX2DSM-001 PDF.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: RS-485.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5CC-RX2DSM-001
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0 E5CC-RX2DSM-001 PDF. 01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RRUN/RESET, alarm),
Interactive display PV/SV E5CC-RX2DSM-001 PDF E5CC-RX2DSM-001 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller OMRON INSTRUCTION Manual. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling OMRON INSTRUCTION Manual.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade OMRON INSTRUCTION Manual.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement E5CC-RX2DSM-001 INSTRUCTION Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5CC-RX2DSM-001 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5CC-RX2DSM-006
OMRON Digital temperature controller E5CC-RX2DSM-006
Size: 48 x 48mm. Control output 1: relay out
OMRON
Digital temperature controller
E5CC-RX2DSM-007
OMRON Digital temperature controller E5CC-RX2DSM-007
Size: 48 x 48mm. Control output 1: relay out
OMRON
Digital temperature controller
E5CC-RX3ASM-005
OMRON Digital temperature controller E5CC-RX3ASM-005
Size: 48 x 48mm. Control output 1: relay out
OMRON
Digital temperature controller
E5CC-RX3ASM-001
OMRON Digital temperature controller E5CC-RX3ASM-001
Size: 48 x 48mm. Control output 1: relay out