Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output.
Auxiliary output: Transistor output: 2 pts (sourcing) E5EC-RX4ASM-000 PDF.
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5
E5EC-RX4ASM-000): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring E5EC-RX4ASM-000 PDF.
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported E5EC-RX4ASM-000 PDF.
UL, CSA, and CE Marking compliance. Appearance: Shielded, M12.
Sensing distance: 4 mm.
Output: PNP.
Model: Operation mode NC.
Aluminum and Iron Both.
Detectable from Long Distances. Size: 48 x 96mm.
Type: power AC/DDC24V with E5EC-RX4ASM-000 Manual.
Shell color: black.
Control output 1: built-in SSR output OMRON INSTRUCTION Manual.
Control output 2: built-in SSR output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2 OMRON INSTRUCTION Manual.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved OMRON INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the sstate of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EC-RX4ASM-000 INSTRUCTION Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E5EC-RX4ASM-000 Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.