Sensing method: Through-beam type.
Sensing distance: 300 mm.
Output type: NPN output.
Output configuration: Dark-ON.
Cable length: 2 m.
Cable length from emitter to amplifier: 0 E5EN-HTPRR2BBD PDF. 5 m.
Compact, Thin-profile.
Photomicrosensor with special amplifier.
Slim amplifier (50 × 7.5 × 12 mm) can be handled like a cable.
Provided with two operation indicators, enabling monitoring from the,
amplifier housing and sensor head
E5EN-HTPRR2BBD
Simple wiring with a 3-conductor cable.
Wide operating voltage range: 12 to 24 VDC. Size: 1/8 DIN 48 × 96 × 78(W × H × D).
Power supply voltage: 24 VAC/VDC.
Input type: Thermocouple or Resistance thermometer E5EN-HTPRR2BBD PDF.
Alarm output: 3.
Control output: Voltage output(for driving SSR) .
Functions: Heater burnout, No; Mounting option units, Yes.
Previous model: None.
These Best-selling General,
purpose Temperature Controllers,
Are Now Even Better.
Controllers now available with analog inputs E5EN-HTPRR2BBD PDF.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models available with a loop break alarm (LBA) and,
heater short alarm (HS alarm).
Manual output provided E5EN-HTPRR2BBD Manual.
Easy setting with 11-segment displays.
New protocol called Modbus is installed in the,
models with communications OMRON INSTRUCTION Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33. Size: 96 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver) OMRON INSTRUCTION Manual.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485 OMRON INSTRUCTION Manual.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mannual, RUN/STOP, alarm), interactive display PV/SV E5EN-HTPRR2BBD INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-HTPRR2BBD Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.