Temperature range: 60 to 110.
Positive / reverse action: positive action (cooling).
Adjustment mode: OFF, ON action.
With the aid of microcomputer, the temperature control can be realized with high precision (0 E5EN-R3H01T-FLK PDF. 1 degrees C).
Combined use of control equipment, adjustable sensitivity.
Attached to facilitate the energy saving operation of the set value conversion function, as well as ease of operation to stop the control function
E5EN-R3H01T-FLK Size: M8, Shielded.
Sensing distance: 2.0 mm.
Connection: M8 connector (3-pin).
Body material: Stainless steel.
Thread length (overall length): 49 (61).
Output configuration: NPN E5EN-R3H01T-FLK PDF.
Operation mode NC.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels) E5EN-R3H01T-FLK PDF.
Modular construction simplifies customization. E3JK-D61 diffuse reflection type,
E3JK direct current mode: mode; shading ON,
Miniature amplifier built-in type photoelectric switchTerminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 3 OMRON INSTRUCTION Manual. 2 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers OMRON INSTRUCTION Manual E5EN-R3H01T-FLK Manual.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling OMRON INSTRUCTION Manual.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Teemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5EN-R3H01T-FLK INSTRUCTION Manual.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5EN-R3H01T-FLK Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.