Appearance: Shielded, M12.
Sensing distance: 4 mm.
Output: PNP.
Model: Operation mode NO.
Aluminum and Iron Both.
Detectable from Long Distances. Case color: Black E5EN-RY3BT-N PDF.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --
E5EN-RY3BT-N
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance E5EN-RY3BT-N PDF. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks E5EN-RY3BT-N PDF.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter OMRON INSTRUCTION Manual.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Appearance: Unshielded.
Sensing surface: Front.
Sensing distance: 2 OMRON INSTRUCTION Manual. 5 mm.
Output configuration: PNP.
Model: Operation mode, NO.
Advanced Performance and Wide.
Range of Selections in a Super.
compact Size.
Only 5.5 × 5 E5EN-RY3BT-N Manual. 5 mm with a built-in Amplifier.
Maximum sensing distance: 2.5 mm. Stable detection even with,
workpiece fluctuations.
Response frequency: 1 kHz OMRON INSTRUCTION Manual.
Low current consumption. E3JK-R32 regression reflection type,
E3JK direct current mode: mode; ON,
Miniature amplifier built-in type photoelectric switchSize: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / mmanual, RUN/STOP, alarm), interactive display PV/SV E5EN-RY3BT-N INSTRUCTION Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E5EN-RY3BT-N Manual.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.