Sensing method: Diffuse reflective.
Appearance: Vertical.
Connection method: Pre-wired .
Sensing distance: 30 to 50 mm.
Model: PNP Open collector output type E6A2-CW3E PDF.
Both Red-light Models and Green,
light Models to Detect a Wide Variety,
of Colors. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: built-in SSR output.
Control output 2: built-in SSR output
E6A2-CW3E
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2 E6A2-CW3E PDF.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E6A2-CW3E PDF.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors OMRON INSTRUCTION sheet.
Also supports remote SP.
Add PV/SV status display function, convenientt to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E6A2-CW3E Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output OMRON INSTRUCTION sheet.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type. Size: M12 (Brass); Double; Unshielded.
Sensing distance: 16 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Long OMRON INSTRUCTION sheet.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. E5AR Digital Controllers offer high speed,
high precision, and multiple I/O and use a 5-digit,
3-row LCD display for high visual.
clarity.
A short sampling period of 50 ms enables use in applications,
requiring high-speed response.
PV, SP, and MV data is displayed simultaneously in a 3-row,
negative LCD display with a backlight.
Multiloop control, cascade control, and proportional control are,
possible with a single Controller.
When using moodels with CompoWay/F communications, initial,
settings can be downloaded and settings can be masked using,
Support Software (CX-Thermo version 4 E6A2-CW3E INSTRUCTION sheet. 0 or higher).
Equipped with calculation functions as a standard (e.g., square,
rooot calculation and broken-line approximation) E6A2-CW3E Manual.
DeviceNet Communications.
Data setting and monitoring can be performed without special,
programming.