Brand: OMRON
Product model: EE-SX670-C1J-R
Name: photomicrosensor
Sort: INSTRUCTION sheet
File language: English
File size: 0.33MB
The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output EE-SX670-C1J-R PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function EE-SX670-C1J-R
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement EE-SX670-C1J-R PDF.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of contrrol output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay EE-SX670-C1J-R PDF EE-SX670-C1J-R Manual. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: -- OMRON INSTRUCTION sheet.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance OMRON INSTRUCTION sheet. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks OMRON INSTRUCTION sheet.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the TTemperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV EE-SX670-C1J-R INSTRUCTION sheet.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs EE-SX670-C1J-R Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
Related products
OMRON
Slot-type Photomicrosensor
EE-SX674
OMRON Slot-type Photomicrosensor  EE-SX674
Appearance: Close mounting. Sensing method:
OMRON
Slot-type Photomicrosensor
EE-SX671P
OMRON Slot-type Photomicrosensor  EE-SX671P
Appearance: T-shaped, slot center 10 mm. Sen
OMRON
Slot-type Photomicrosensor
EE-SX672P
OMRON Slot-type Photomicrosensor  EE-SX672P
Appearance: T-shaped, slot center 10 mm. Sen
OMRON
Slot-type Photomicrosensor
EE-SX671
OMRON Slot-type Photomicrosensor  EE-SX671
Appearance: T-shaped, slot center 10 mm. Sen