LK166
Home >> Download >> OMRON >> Manual Download >> OMRON EJ1G-HFUB-NFL2 INSTRUCTION sheet PDF

OMRON EJ1G-HFUB-NFL2 INSTRUCTION sheet PDF

Brand: OMRON
Product model: EJ1G-HFUB-NFL2
Name: temperature controller
Sort: INSTRUCTION sheet
File language: English
File size: 0.53MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output EJ1G-HFUB-NFL2 PDF.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function EJ1G-HFUB-NFL2
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance EJ1G-HFUB-NFL2 PDF.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay EJ1G-HFUB-NFL2 PDF.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Sensing method: Diffuse-reflective Sensors OMRON INSTRUCTION sheet.
Appearance: Horizontal.
Connection method: Pre-wired.
Sensing distance: 200 mm.
Functions: --.
Model: PNP output.
Ordering Information.
Built-in Amplifier Photoelectric Sensors. Appearance: Shielded, M30.
Sensing distance: 8 mm.
Output configuration: DC 2-wire, (3)-(4) pin arrangement OMRON INSTRUCTION sheet.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connecttor Models also available EJ1G-HFUB-NFL2 Manual. Size: 48 x 96mm.
Type: power AC/DC24V with OMRON INSTRUCTION sheet.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: transfer output (special terminal).
Remote SP:4 to 20mA input.
Communication: RS-232C.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV EJ1G-HFUB-NFL2 INSTRUCTION sheet.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output EJ1G-HFUB-NFL2 Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.