Insulation method: Photocoupler.
Operation indicator: Yes (yellow).
Zero cross function: Yes.
Applicable output load: 150 A, 180 to 480 VAC.
Rated input voltage: 5 to 24 VDC G3PW-A245EC-S-FLK PDF.
High-power, Load-control SSRs with.
High Current of 75 or 150 A and High.
Voltage of 240 or 480 VAC.
RoHS compliant.
Models also available with no zero cross.
Replaceable power elements.
Conforms to cULus standards and EN standards (TÜV certification)
G3PW-A245EC-S-FLK Input capacity: 16 points.
Rated current (ON current):
0.5 A/output, 4.0 A/common.
Internal I/O common: NPN.
Residual voltage: 1.2 V max.
(0.5 ADC, between each output,
terminal and the G terminal) G3PW-A245EC-S-FLK PDF.
Leakage current: 0.1 mA max.
ON delay: 0.5 ms max.
OFF delay: 1.5 ms max.
Number of circuits per common: 16 points/common.
Output indicators: LED display (yellow).
Isolation method: Photocoupler isolation.
I/O power supply method: Supply by I/O power supply G3PW-A245EC-S-FLK PDF.
Unit power supply current consumption: 90 mA max.
(for 200 G3PW-A245EC-S-FLK Manual. 4 to 26.4-VDC power supply voltage)
I/O power supply current con sumption: 5 mA max.
(for 20.4 to 26.4-VDC power supply voltage)
Weight: 180 g max.
Expansion functions: Enabled.
Output handling for communications errors:
Select either hold or clear OMRON INSTRUCTION MANUAL.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit OMRON INSTRUCTION MANUAL. )
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance OMRON INSTRUCTION MANUAL. 100-A-max. Leakage Current, No Bleeder.
Resistor Required.
1 mA to 500 mA micro-load switching.
Switch to both AC and DC with no polarity.
Switch for a wide range of voltages; 19 G3PW-A245EC-S-FLK INSTRUCTION MANUAL. 2 to 264 VAC, 19.2 to 125 VDC.
Switch full- and half-wave rectifier AC loads.
Same sizes and terminal arrangements as OMRON Power,
Relay MY Series.
Operating indicator provided.
Switch MY Series (without bleeder resistor) G3PW-A245EC-S-FLK Manual.
Superior surge absorption with a built-in varistor.
Optimum SSR to control minute load, valves, and solenoids.