Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 0.9A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1.5 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red) ZJ-BAS-MC15A PDF.
Main functions: Ion balance adjustment (Automatic and manual)
ZJ-BAS-MC15A
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0 ZJ-BAS-MC15A PDF. 1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 0.6 kg (Approx. 1.2 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, L-mounting bracket, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues ZJ-BAS-MC15A PDF. Actuator: Short hinge lever.
Approved Standards: UL CSA EN.
Small, High-precision Enclosed Switch.
Small, High-precision Enclosed Switches with Built-in Basic,
Switches for High Repeatability and Durability of 10 Million,
Operations Minimum.
Same mounting pitch as Z Basic Switch.
Requires less operating force than conventional limit switches.
Lineup includes modes with operation indicators for easy,
maintenance and inspection.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for Information on approved models.). Shape: Heat-resistant, cylindrical.
Dimensions: M12 x 22 mm.
Sensing distance: 2 mm.
Resolution: 1 μm.
High-accuracy Detection of Metal Workpiece Dispplacement ZJ-BAS-MC15A datasheet.
Sensor Heads support a wide variety of applications.
Linearity can be adjusted for non-ferrous metals,
such as SUS and aluminum, using the material selection function.
Simple linearity compensation (teaching).
Easily perform calculation for two Sensors by using a Calculating Unit ZJ-BAS-MC15A datasheet.
Prevent mutual interference for up to five Units by using a Calculating Unit.