LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AJ35PTF-24S datasheet PDF

MITSUBISHI AJ35PTF-24S datasheet PDF

Brand: MITSUBISHI
Product model: AJ35PTF-24S
Name: Silicon controlled output module
Sort: PDF datasheet
File language: English
File size: 7.99MB
Program memory capacity 14K.
Input and output points to the maximum 512 points.
A scan cycle of PLC must pass through three stages: input sampling, program execution and output refresh.
PLC in the input sampling phase: first of all, in order to scan the sequence of all existing input latches in the input terminal of the state or input data read,
And write it into the corresponding input status register,
Refresh the input, then close the input port, enter the program execution stage AJ35PTF-24S PDF AJ35PTF-24S Cable length: 30 meters.
For connection between GOT and CRT. I/O slots: 3 slots.
Outline dimension: 255*130.
CPU basic board can be plugged into 1 power modules,
1 CPU components and a maximum of 2, 3, 5, or 8 single slot size special function components and I/O components are respectively inserted and arranged AJ35PTF-24S PDF.
Expansion ports are arranged on both sides of the base plate,
For connecting the expansion board for.
Up to 3 extension substrates. DC input points: 4 points.
Input voltage and current: 7mA, DC24V.
Input response time: 10ms.
4 point /1 a public side.
Positive / negative sharing.
Output points: 4 points AJ35PTF-24S PDF.
Output voltage and current: DC24V/AC240V, 2A/1 point, 8A/1 common end.
Output response time: 12ms.
4 point /1 a public side.
Output form: relay.
24 point terminal station.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc..
MITSUBISHI PLC program simullation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of thee program AJ35PTF-24S datasheet AJ35PTF-24S datasheet.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation.
Related products
MITSUBISHI
Transistor output module
AJ35PJ-8T1
MITSUBISHI Transistor output module
 AJ35PJ-8T1
Output points: 8 points. Output voltage and c
MITSUBISHI
Silicon controlled output module
AJ35PTF-24S
MITSUBISHI Silicon controlled output module
 AJ35PTF-24S
Output points: 24 points. Output voltage and
MITSUBISHI
Melsecnet module
AJ35PP-CNV-SI
MITSUBISHI Melsecnet module AJ35PP-CNV-SI
MELSECNET/MINI -S3 data link system, A2C sy
MITSUBISHI
Transistor output module
AJ35PTF-24T
MITSUBISHI Transistor output module
 AJ35PTF-24T
Output points: 24 points. Output voltage and