LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AJ35TJ-48DT datasheet PDF

MITSUBISHI AJ35TJ-48DT datasheet PDF

Brand: MITSUBISHI
Product model: AJ35TJ-48DT
Name: DC input / transistor output module
Sort: PDF datasheet
File language: English
File size: 7.99MB
I/O slots: 2 slots.
Can you install the power module.
Outline dimension: 155*130.
There are two types of extended floor,
A power module can be inserted, and the other one is not.
The choice of any type of substrate depends on the total DC5V current consumption and the power supply on the CPU main substrate AJ35TJ-48DT PDF.
If the total demand is less than the power output, no additional power supply,
Then you can choose a more economical expansion board AJ35TJ-48DT
Both ends of the main base plate of the CPU have an expansion interface, and can be used for extending the cable connection. Input type: DC input, positive common end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA AJ35TJ-48DT PDF.
External connection: 3 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
When installing the module can choose to use the DIN guide rail or screw mounting AJ35TJ-48DT PDF.
Can be used for the 3 wire sensor input wiring. 10BASE2.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digital signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal.
So the standard telecommunication number, the conversion between the number of operations to use a variety of computing.
This requires the resolution of the analog unit and the standard electrical signal.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simplified.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Need to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers. Poor visibility and operability.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination oof the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AJ35TJ-48DT datasheet.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic AJ35TJ-48DT datasheet.
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
Relay output module
AJ35TJ-8R
MITSUBISHI Relay output module
 AJ35TJ-8R
Output points: 8 points. Output voltage and c
MITSUBISHI
AC100V input module
AJ35TB1-16A
MITSUBISHI AC100V input module AJ35TB1-16A
AC input points: 16 points. Input voltage and
MITSUBISHI
DC input module
AJ35TJ-8D
MITSUBISHI DC input module AJ35TJ-8D
DC input points: 8 points. Input voltage and
MITSUBISHI
Silicon controlled output module
AJ35TJ-8S1
MITSUBISHI Silicon controlled output module
 AJ35TJ-8S1
Output points: 8 points. Output voltage and c