MITSUBISHI AJ65BTB2-16DT datasheet PDF

Brand: MITSUBISHI
Product model: AJ65BTB2-16DT
Name: DC input / transistor output module
Sort: PDF datasheet
File language: English
File size: 8.82MB
Output type: transistor output, drain type.
Output points: 16 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.5A.
External connection: 2 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AJ65BTB2-16DT PDF.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ65BTB2-16DT Applicable model: A975/970/960GOT (-B).Points: 32 points
.
Rated voltage: DC24V.
Connection type: connector
.
Three remote components can be connected to the CC-LINK system AJ65BTB2-16DT PDF.
Remote I/O: refers to those who require only the ON/OFF control function of the field components, such as digital I/O or pneumatic valve, etc..
In this type of communication can only be carried out in the bit data.
Remote components: refers to those that require processing of the register data of the field components, such as analog I/O and counters, etc..
In this type of component, in addition to the bit data can be carried out in the register data communication AJ65BTB2-16DT PDF.
Intelligent remote: this type of component is to allow the main station or other stations to access the action, to collect data and control the local PLC station,
GOTS and programmer interface unit are of this type. Number of channels: 2 channels.
Sensing method and temperature range: PT100.
A1S64TC series component is a kind of temperature controller combined with ANS series CPU.
Components with temperature measurement input and built-in PID algorithm control output, can be used in a variety of temperature control occasions.
Each component controls up to 4 loops at most.
Thermocouple input or PT100 3 wire temperature sensor input.
Control output switching signal for the output of the transistor.
BW is a signal with broken line detection function. CPU-A8UPU/A8PUJ connection.Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Optical data communication line.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
IIntegral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure AJ65BTB2-16DT datasheet AJ65BTB2-16DT datasheet.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
output module
AJ65BTC1-32T
MITSUBISHI output module AJ65BTC1-32T
Points: 32 points . Rated voltage: DC24V. Con
MITSUBISHI
DC input / transistor output module
AJ55TB32-16DT
MITSUBISHI DC input / transistor output module AJ55TB32-16DT
DC input points: 8 points. Input voltage and
MITSUBISHI
DC input module
AJ65BTB2-16D
MITSUBISHI DC input module AJ65BTB2-16D
Input type: DC input, positive pulic end / n