Brand: MITSUBISHI
Product model: AJ65SBTB2-16T
Name: Transistor output module
Sort: PDF datasheet
File language: English
File size: 8.82MB
Control axis number: 2 axes (independent, straight line arc interpolation at the same time)
Number of stations: 4 stops.
Station type: intelligent equipment station.
Configuration of master / local station,
In addition to the other site network with different CC-Link in addition to the main station and the remote station configuration can also be the main station and the local station configuration AJ65SBTB2-16T PDF AJ65SBTB2-16T
A local PLC can communicate with the master station PLC and other remote workstations.
MITSUBISHI PLC hardware implementation
Hardware implementation is mainly for the control cabinet and other hardware design and field construction.
Design control cabinet and the operating table and other parts of the electrical wiring diagram and wiring diagram AJ65SBTB2-16T PDF.
Electrical interconnection diagram of each part of the design system.
According to the construction drawings of the site wiring, and carry out a detailed inspection.
Because the program design and hardware implementation can be carried out at the same time,
So the design cycle of the MITSUBISHI PLC control system can be greatly reduced.
MITSUBISHI PLC online debugging AJ65SBTB2-16T PDF.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on step by step.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be. Self service (IN, OUT): SI optical cable.
Other aspects (IN, OUT): SI optical cable.
Data link anomaly Bureau bypass.
Inter agency extension.
Cable transformation. Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 1 line /1 line type.
40 pin connector type (FCN connector type).
Through the 40 pin connector type (FCN connector type) can be connected to a variety of devices.
Can be installed along the 6 direction.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the ttimeliness is strong AJ65SBTB2-16T datasheet.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness AJ65SBTB2-16T datasheet.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.
Related products
MITSUBISHI
DC input / transistor output module
AJ65SBTB32-16KDT2
MITSUBISHI DC input / transistor output module AJ65SBTB32-16KDT2
Input type: DC input, positive common end. In
MITSUBISHI
Optical repeater module
AJ65SBT-RPG
MITSUBISHI Optical repeater module AJ65SBT-RPG
Description: GI type optical fier cale with
MITSUBISHI
DC input / transistor output module
AJ65SBTB1-32KDT2
MITSUBISHI DC input / transistor output module AJ65SBTB1-32KDT2
Input type: DC input, positive common end. In
MITSUBISHI
Transistor output module
AJ65SBTB1-8TE
MITSUBISHI Transistor output module AJ65SBTB1-8TE
Output type: transistor output, source. Outpu