MITSUBISHI AJ65SBTB2N-8A datasheet PDF

Brand: MITSUBISHI
Product model: AJ65SBTB2N-8A
Name: Input module
Sort: PDF datasheet
File language: English
File size: 8.82MB
2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program AJ65SBTB2N-8A PDF.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage AJ65SBTB2N-8A
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load AJ65SBTB2N-8A PDF.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest AJ65SBTB2N-8A PDF.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. QCPU (Q mode) bus connection.
1 joint.
Applicable model: A956WGOT. JEMANET (OPCN-1) interface unit master station.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is callled the I/O delay time effect AJ65SBTB2N-8A datasheet.
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CCPU AJ65SBTB2N-8A datasheet.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive.
Related products
MITSUBISHI
Transistor output module
AJ65SBTB2-16T
MITSUBISHI Transistor output module AJ65SBTB2-16T
Output type: transistor output, drain type. O
MITSUBISHI
Input module
AJ65SBTB1-32D
MITSUBISHI Input module AJ65SBTB1-32D
Input type: DC input, positive pulic end / n
MITSUBISHI
DC input / transistor output module
AJ65SBTB1-32DT3
MITSUBISHI DC input / transistor output module AJ65SBTB1-32DT3
Input type: DC input, positive common end. In