MITSUBISHI AJ72QBR15 datasheet PDF

Brand: MITSUBISHI
Product model: AJ72QBR15
Name: Coaxial cable module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Type of input: DC leakage.
Input points: 32 points.
Input voltage: 12/24.
Input current: 3/7mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions AJ72QBR15 PDF AJ72QBR15
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and complex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced AJ72QBR15 PDF. Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA AJ72QBR15 PDF.
External connection: 3 wire.
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. 8 slots.
Power supply unit.
QnAS series unit installation.
High speed access.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load currennt and voltage AJ72QBR15 datasheet.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnected from the load AJ72QBR15 datasheet.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
Related products
MITSUBISHI
Network module
AJ72P25
MITSUBISHI Network module AJ72P25
SI-200/250 fier optic cale. Doule loop. ME
MITSUBISHI
MELSECNET/MINI-S3 module
AJ72T35
MITSUBISHI MELSECNET/MINI-S3 module AJ72T35
Twisted pair cale. Single us. Remote I/O st
MITSUBISHI
Coaxial cable module
AJ72QLR25
MITSUBISHI Coaxial cable module AJ72QLR25
3C-2V/5C-2V coaxial cale. Doule loop. Remot
MITSUBISHI
MELSECNET/MINI-S3 module
AJ72PT35
MITSUBISHI MELSECNET/MINI-S3 module AJ72PT35
Fier optic cale / twisted pair cale. Singl