LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AX40Y50C datasheet PDF

MITSUBISHI AX40Y50C datasheet PDF

Brand: MITSUBISHI
Product model: AX40Y50C
Name: DC input / transistor output module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0 AX40Y50C PDF. 5A.
External connection: 1 line /1 line type.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup AX40Y50C
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AX40Y50C PDF. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 0.2ms below, below 1.5ms, 5ms below, 10ms the following.
Rated input voltage / current: DC12V/11mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/0.5A.
External connection: 3 line /2 line type AX40Y50C PDF.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Input voltage range: DC110/125V.
Output voltage: DC5V.
Output current: 8A.
For Q4ARCPU.
The control module monitors the power supply, the error
CPU state,
And its own error state.
It sends out
Error signal a6raf and open the corresponding
Relay output.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accordding to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AX40Y50C datasheet.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% AX40Y50C datasheet.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
DC input / relay output module
AX40Y10C
MITSUBISHI DC input / relay output module AX40Y10C
Input points: 16 points. Input voltage and cu
MITSUBISHI
DC input / transistor output module
AX40Y50C
MITSUBISHI DC input / transistor output module AX40Y50C
Input points: 16 points. Input voltage and cu
MITSUBISHI
Input module
AX40
MITSUBISHI Input module AX40
Input points: 16 points. Voltage: DC12/24V. C