LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AX50 datasheet PDF

MITSUBISHI AX50 datasheet PDF

Brand: MITSUBISHI
Product model: AX50
Name: Input module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0 AX50 PDF. 1A.
External connection: 3 line /2 line type.
Sensor connector type (E-CON type) AX50
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input and output points: 2048 points.
Input / output data points: 2048 points.
Program capacity: 30K.
Basic command processing speed (LD command) s:0 AX50 PDF. 15.
Integral type: the PLC components are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way AX50 PDF. Easy maintenance.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
User program storage capacity: it is aa measure of how much the user application can store the number of indicators AX50 datasheet.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General llogical operation instructions each account for 1 words AX50 datasheet. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Related products
MITSUBISHI
AC input / silicon controlled output module
AX10Y22C
MITSUBISHI AC input / silicon controlled output module AX10Y22C
Input points: 16 points. Input voltage and cu
MITSUBISHI
Transistor leakage type output module
A1SY50
MITSUBISHI Transistor leakage type output module A1SY50
Output type: transistor drain. Output points:
MITSUBISHI
Input module
AX81-S2
MITSUBISHI Input module AX81-S2
Input points: 32 points. Voltage: DC48/60V. C
MITSUBISHI
Input module
AX20
MITSUBISHI Input module AX20
Input points: 16 points. Voltage: AC200 240