LK166
Home >> Download >> MITSUBISHI >> Catalog Download >> MITSUBISHI AX80Y14CEU datasheet PDF

MITSUBISHI AX80Y14CEU datasheet PDF

Brand: MITSUBISHI
Product model: AX80Y14CEU
Name: DC input / relay output module
Sort: PDF datasheet
File language: English
File size: 2.54MB
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
20 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor AX80Y14CEU PDF AX80Y14CEU
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc AX80Y14CEU PDF. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AX80Y14CEU PDF.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. CPU-A8UPU/A8PUJ connection.Cable 1.2m for the expansion of the floor, the expansion of a floor for every 1 units.Input voltage range: DC110/125V.
Output voltage: DC5V.
Output current: 8A.
For Q4ARCPU.
The control module monitors the power supply, the error
CPU state,
And its own error state.
It sends out
Error signal a6raf and open the corresponding
Relay output.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined accordinng to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AX80Y14CEU datasheet.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% AX80Y14CEU datasheet.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
DC input / relay output module
AX80Y10C
MITSUBISHI DC input / relay output module AX80Y10C
Input points: 16 points. Input voltage and cu
MITSUBISHI
DC input / transistor output module
AX80Y80C
MITSUBISHI DC input / transistor output module AX80Y80C
Input points: 16 points. Input voltage and cu
MITSUBISHI
DC input / relay output module
AX80Y14CEU
MITSUBISHI DC input / relay output module AX80Y14CEU
Input points: 16 points. Input voltage and cu