The built-in I/O function (Location: 1 axis) of the pulse output is converted to a differential drive output.Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: transistor.
Power consumption: 20W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87 FR-A8AY PDF.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard
FR-A8AY
Continuous scanning function, to define the operation cycle for the application of the continuous scan time.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).
Note recording function, Component annotation can be recorded in the program register FR-A8AY PDF.
Since the FX2n series have the following features: the maximum range of inclusive of the standard features, program execution faster, the full complement of communication function, suitable for different countries in the world, and the power to meet a large number of special function modules of individual needs,
It can provide maximum flexibility and control capability for your factory automation applications FR-A8AY PDF.
Control 16~256 point.
Built in 8K capacity of the RAM memory, the maximum can be extended to 16K.
CPU arithmetic processing speed of 0.08 S/ basic instructions.
On the right side of the FX2N series can be connected to the input and output expansion modules and special function modules.
The basic unit is built in the 2 axis independent maximum 20kHz positioning function (transistor output type).
Quick disconnect the terminal block, which adopts excellent maintainability to quickly disconnect the terminal blocks, even if the cable is then replaced by the cable. MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 500kw.
SLD converter rated current: 1094A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON.
Standby power management can be carried out by means of frequency converter to realize the power consuumption reduction of standby time FR-A8AY datasheet.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the correspondinng signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation FR-A8AY datasheet.
Can reduce the power consumption in the stop.