MITSUBISHI FR-HEL-H0.4K datasheet PDF

Brand: MITSUBISHI
Product model: FR-HEL-H0.4K
Name: DC reactor
Sort: PDF datasheet
File language: English
File size: 8.41MB
"MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 7.5KW.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification FR-HEL-H0.4K PDF.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter) FR-HEL-H0.4K
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "Power: 22kw FR-HEL-H0.4K PDF.
Voltage: 400V.
There are 100% braking torque output in continuous regeneration, which can correspond to the continuous regeneration operation of the pipeline control.
There is no need to install the braking unit for each frequency converter, which can reduce the comprehensive space and reduce the comprehensive cost.
Renewable energy can be used for other frequency converter, excess energy back to the grid, to achieve energy saving FR-HEL-H0.4K PDF. MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 560KW.
The main circuit of the inverter can be divided into two categories in general: voltage type is the voltage source of the DC converter for AC inverter,
The filtering of the DC circuit is the capacitance; the current mode is the DC conversion of the current source to the AC inverter,
The DC loop filter is the inductor.
Why is the frequency of the inverter voltage proportional to tthe change?
The electromagnetic torque of any motor is the result of the interaction between the current and the magnetic flux, the current is not allowed to exceed the rated value, otherwise it will cause the heating of the mmotor FR-HEL-H0 FR-HEL-H0.4K datasheet. 4K datasheet.
Therefore, if the magnetic flux decreases, the electromagnetic torque will decrease, which leads to the reduction of the load carrying capacity.
Related products
MITSUBISHI
DC reactor
FR-HEL-H22K
MITSUBISHI DC reactor FR-HEL-H22K
Power: 22kw. Purpose: to suppress the power h
MITSUBISHI
DC reactor
FR-HEL-H55K
MITSUBISHI DC reactor FR-HEL-H55K
Power: 55kw. Purpose: to suppress the power h
MITSUBISHI
DC reactor
FR-HEL-H45K
MITSUBISHI DC reactor FR-HEL-H45K
Power: 45kw. Purpose: to suppress the power h
MITSUBISHI
DC reactor
FR-HEL-H11K
MITSUBISHI DC reactor FR-HEL-H11K
Power: 11kw. Purpose: to suppress the power h